It is in response to the overwhelming clamor from our customers for a product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are reduced to insignificant levels, if not eliminated --- because in some countries,the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if power is exported to the grid, thus, the consumers will be charged for power even if it is given to the grid, and this is the problem
This is the 2nd generation grid tie inverter with limiter.
With the 2nd generation GTIL,we integrated the limit function inside the GTI-We call this internal limiter.In this way,No additional limiter module is needed,reduced customer's cost,more easier for installation.But in case customer install inverter far away from the main circuit breaker,we also enable the 2nd GTIL work with stand-alone limiter,we call this-external limiter.For sure,the inverter can work under normal Grid tie-no limit mode,just set on the nice LCD and save your setting.
Technical Data
Continuous Power Output | 980W |
Peak Power Output | 1000W |
Input DC Voltage Range | 22V-60V/45V ~ 90V |
Peak power tracking voltage | 25V-60V/50V-90V |
AC Output Voltage Range | 90V-140V/ 190VAC ~ 260VAC |
Output Frequency | 46Hz~65Hz |
Standby Power Consumption | <0.5W |
Total Harmonic Distortion | <5% |
Peak Inverter Efficiency | 92% |
MPPT Efficiency | 99% |
Power Factor | 0.99 |
Output Wave Form | Pure Sine Wave |
MPPT Function | Yes |
Over Current Protection | Yes |
Over Temperature Protection | Yes |
Reverse Polarity Protection | Yes |
Anti-Island Protection | Yes |
Stackable | Yes |
Weight ( Kg) | 3.6kg |
Dimensions (W x H x D) | 322x196x88 mm |
Description:
a: DC input , for solar panels connection
b: Connector for external limiter
c: Connector for internal limiter
d: AC output , use AC cable to connect to home grid
Sensor Clamp :
Packing List :
1. Solar Grid Inverter with Limiter(built-in)-----1unit
2. AC cable-------------1 pcs
3. Internal type Limiter clamp with sensor & 2m cable----1pcs
4. Warranty card----1pcs
5. User Manual ----1pcs
How to use the Inverter ?
1. Standard Grid Tie Inverter Model
1.1. The Grid Tie inverter converts DC power produced by Solar Panels to AC, connects to the grid and feed all of the power available from the panels to the AC load.
1.2. All excess power that is not needed by the load is then exported to the Grid.
1.3. If the Grid fails, then the Grid Tie Inverter will turn off. When the Grid comes back on line. The Grid Tie Inverter will again supply power to the load and any excess power is exported to the Grid again.
1.4. If the Solar Panel is producing less power and the GTI cannot deliver all the power needed by the load, then power will be supplemented by the Grid.
1.5. Power Meters (Except smart meter) are not aware of the direction of Power flow. The user then pays for the power exported and delivered by the Grid.
2. Using Grid Tie Inverter With Limiter Model
2.1 The Grid Tie Inverter with Limiter delivers only the power needed by the load and prevents delivering excess power hence avoids excess power in going back to the Grid.
2.2 The heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM). The LM continuously sampled the power needed by the load through the current sensor connected after the Main Circuit Breaker. The LM then will process the signal. It then sends signal to Grid Tie Inverter how much power to deliver to the load in real time.
2.3 The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its work automatically.
3. Installation of GTIL With Internal Limiter
3.1 This installation is not require an additional limiter module,Installation is much easier.Clamp the current sensor cable to the hot wire to measure the current,the internal limiter will auto detect the load power and control the inverter output power,excess power will be well controlled.
3.2 External protective device including dc and ac SPD(Surge protection device),dc and ac breaker,etc is recommended to installed in the system.
4.Limiter Setting on the LCD of the inverter:
The GTIL include three working mode:Work as normal GTI without power limitation.Work under Internal limiter mode and Work under External limiter mode,Pls make your setting on the LCD and save it,details setting operation,pls read the GTI manual.
5 Limiter Module Specification
1. Clamp sensor- Max 100A
2. Wattmeter- Max 9999w
3. Terminal Block-Max 20A
4. Receptacle- max 2000w
5. Clamp sensor signal- 5v AC max mA
6. DC signal Cable- 5v DC, max mA
Solar Power Grid Tie Inverters List
Model | Power | Generation | Energy Type | Input voltage | Output voltage | Limiter | LCD | Aliexpress Link |
1000G2 | 1000w | 2nd | Solar | 22v-60v/45v-90v | 90v-130v/195v-255v | no | yes | Click to check |
2000G2 | 2000w | 2nd | Solar | 45v-90v | 195v-255v | no | yes | Click to check |
1000G2TIL | 1000w | 2nd | Solar | 22v-60v/45v-90v | 90v-130v/195v-255v | yes | yes | Click to check |
2000G2TIL | 2000w | 2nd | Solar | 45v-90v | 195v-255v | yes | yes | Click to check |
500G-LCD | 500w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | yes | Click to check |
600G-LCD | 600w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | yes | Click to check |
1000G-LCD | 1000w | 1st | solar | 22v-60v/45v-90v | 90v-130v/195v-255v | no | yes | Click to check |
1500G-LCD | 1500w | 1st | solar | 45v-90v | 90v-130v/195v-255v | no | yes | Click to check |
2000G-LCD | 2000w | 1st | solar | 45v-90v | 195v-255v | no | yes | Click to check |
250G | 250w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | no | Click to check |
300G | 300w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | no | Click to check |
500G | 500w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | no | Click to check |
600G | 600w | 1st | solar | 10.8v-30v/22v-60v | 90v-130v/195v-255v | no | no | Click to check |
1000G | 1000w | 1st | solar | 22v-60v/45v-90v | 90v-130v/195v-255v | no | no | Click to check |
1500G | 1500w | 1st | solar | 45v-90v | 90v-130v/195v-255v | no | no | Click to check |
2000G | 2000w | 1st | solar | 45v-90v | 195v-255v | no | no | Click to check |
If the distance of meter and inverter is too long , you will need the External Limiter . Note: The external limiter is not included in package .
If you need the external limiter , please order from this link:
3M CABLE External Limiter 3M CABLE External Limiter
14 days no reason to return . A purchase ,life long service .
Why to choose GAIA grid tie Inverters ?
1. Advanced patented technology, MPPT efficiency is higher.
2. High-quality imported components, more stable quality, lower failure rate. Significantly longer life, more than 10 years.
3. Each inverter need to pass twice testing (16 hours) before leaving factory.
4. Warranty: 2 years of free maintenance and replacement, lifetime technical support.
5. Low cost and easy installation .
6. Free combination.
7. Combination of SGPV does not interact.
8. Improving the efficiency of the entire solar power system.
9. Low power consumption.
CE ROHS SGS Certification
Warraning:
Please do not choose a cheap power inverter.
Low-cost power inverter use low-quality components, low efficiency, poor stability.
Poor quality power inverter might damage the appliances, and even cause fires and explosions.
Please select CE or other certified products.Shipping :
We will ship item by FEDEX/DHL/EMS, it will take about 7 days to arrive your address .
If bulk order , we will suggest to shipping by boat. Thank you .
Warranty and Return Policy
1. GAIA NEW ENERGY is your trusted partner for long term business.We arethe MANUFACUTER of the solar inverter. We are responsible forthe quality of the inverter. The inverter has 2 years guarantee. We provide technical support and service for the inverter the whole life. All inverters would be double tested before shipment to be guaranteed in brand new condition and work perfectly.
2. Returns for exchange are permitted and must be initiated by the buyer within 4 days of receipt. All return items must be in their original condition. Return shipping and handling charge will be at the buyer's expense first. Please do contact with us for return address, details and any other issues.
3. We will not be responsible for any delay during delivery including but not limited to the customs package checking, strike, force majeure, etc.
4. We can declare lower value on the invoice for the duties reason, which does not reflect the total price you paid or the market value of the product. It may not apply to countries with different tariff rules. We are not responsible for any custom duty or import tax.
5. In case there is problem with your order, make sure CONTACT US before leaving negative feedback. Leaving negative feedback without communication is a violation of feedback policy.
6. Please leave us message if you have any question, we will reply in 24 hours, thank you!